On-line Testing of Calibration of Process Instrumentation Channels in Nuclear Power Plants. Phase 2, Final Report

On-line Testing of Calibration of Process Instrumentation Channels in Nuclear Power Plants. Phase 2, Final Report
Author :
Publisher :
Total Pages : 319
Release :
ISBN-10 : OCLC:68356647
ISBN-13 :
Rating : 4/5 ( Downloads)

Book Synopsis On-line Testing of Calibration of Process Instrumentation Channels in Nuclear Power Plants. Phase 2, Final Report by :

Download or read book On-line Testing of Calibration of Process Instrumentation Channels in Nuclear Power Plants. Phase 2, Final Report written by and published by . This book was released on 1995 with total page 319 pages. Available in PDF, EPUB and Kindle. Book excerpt: The nuclear industry is interested in automating the calibration of process instrumentation channels; this report provides key results of one of the sponsored projects to determine the validity of automated calibrations. Conclusion is that the normal outputs of instrument channels in nuclear plants can be monitored over a fuel cycle while the plant is operating to determine calibration drift in the field sensors and associated signal conversion and signal conditioning equipment. The procedure for on-line calibration tests involving calculating the deviation of each instrument channel from the best estimate of the process parameter that the instrument is measuring. Methods were evaluated for determining the best estimate. Deviation of each signal from the best estimate is updated frequently while the plant is operating and plotted vs time for entire fuel cycle, thereby providing time history plots that can reveal channel drift and other anomalies. Any instrument channel that exceeds allowable drift or channel accuracy band is then scheduled for calibration during a refueling outage or sooner. This provides calibration test results at the process operating point, one of the most critical points of the channel operation. This should suffice for most narrow-range instruments, although the calibration of some instruments can be verified at other points throughout their range. It should be pointed out that the calibration of some process signals such as the high pressure coolant injection flow in BWRs, which are normally off- scale during plant operation, can not be tested on-line.


On-line Testing of Calibration of Process Instrumentation Channels in Nuclear Power Plants. Phase 2, Final Report Related Books

On-line Testing of Calibration of Process Instrumentation Channels in Nuclear Power Plants. Phase 2, Final Report
Language: en
Pages: 319
Authors:
Categories:
Type: BOOK - Published: 1995 - Publisher:

DOWNLOAD EBOOK

The nuclear industry is interested in automating the calibration of process instrumentation channels; this report provides key results of one of the sponsored p
On-line Testing of Calibration of Process Instrumentation Channels in Nuclear Power Plants
Language: en
Pages: 338
Authors: H. M. Hashemian
Categories: Nuclear power plants
Type: BOOK - Published: 1995-11-01 - Publisher:

DOWNLOAD EBOOK

This report provides key results of a three-year experimental and theoretical research and development effort performed under the auspices of the U.S. Nuclear R
On-line Testing of Calibration of Process Instrumentationchannels in Nuclear Power Plants. Phase 2. Final Report
Language: en
Pages:
On-line Calibration of Process Instrumentation Channels in Nuclear Power Plants
Language: en
Pages: 12
Authors:
Categories:
Type: BOOK - Published: 1995 - Publisher:

DOWNLOAD EBOOK

An on-line instrumentation monitoring system was developed and validated for use in nuclear power plants. This system continuously monitors the calibration stat
On-Line Testing of Calibration of Process Instrumentation Channel in Nuclear Power Plants
Language: en
Pages:
Authors: H. M. Hashemian
Categories:
Type: BOOK - Published: 1995-11-01 - Publisher:

DOWNLOAD EBOOK